78 HP ProLiant ML350 Generation 4p Server User Guide
Installing a Redundant Fan
1. Power down the server ("Powering Down the Server" on page 25).
2. Extend the server from the rack, if applicable ("Extending the Server from
the Rack" on page 26
).
3. Remove the front bezel door, if necessary ("Removing the Front Bezel
(Tower Model)" on page 27
).
4. Remove the access panel ("Removing Access Panel" on page 27
).
5. Install the redundant fan assembly and tighten the thumbscrew.
6. Connect the redundant fan cable to the redundant fan connector on the
system board.
7. Replace the front bezel ("Removing the Front Bezel (Tower Model)" on page
27), if applicable.
8. Replace the access panel ("Removing Access Panel" on page 27
).