Hardware options installation 50
7.
Install the FBDIMM.
8. Install the memory board ("Removing and installing a memory board" on page 47).
9. Install the processor air baffle.
10. Install the access panel (on page 26).
11. Do one of the following:
o Close or install the tower bezel, as needed.
o Slide the server back into the rack.
12. If you are installing FBDIMMs in an online spare or mirrored memory configuration, use RBSU to
configure this feature ("Configuring online spare memory" on page 83).
Hot-plug hard drive options
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
If only one hard drive is used, install it in the bay with the lowest device number ("SAS and SATA
device numbers" on page 15).
Hard drives must be SFF types.
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.