Component identification 11
System maintenance switch
Position Default Function
S1
Off Off = iLO 4 security is enabled.
On = iLO 4 security is disabled.
S2
Off
Off = System configuration can be
changed.
On = System configuration is locked.
S3
Off Reserved
S4
Off Reserved
S5
Off Off = Power-on password is enabled.
On = Power-on password is disabled.
S6
Off Off = No function
On = ROM reads system configuration
as invalid.
S7
Reserved
S8
Reserved
S9
Reserved
S10
Reserved
S11
Reserved
S12
Reserved
To access the redundant ROM, set S1, S5, and S6 to on.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.
Mezzanine connector definitions
Item PCIe
Mezzanine connector 1
x16, Type A mezzanine card only
Mezzanine connector 2*
x16, Type A or B mezzanine card
*When installing a mezzanine option on mezzanine connector 2, processor 2 must be installed.
DIMM slot locations
DIMM slots are numbered sequentially (1 through 8) for each processor. The supported AMP modes use the
alpha assignments for population order, and the slot numbers designate the DIMM slot ID for spare
replacement.