HP E1459A SCPI Command Reference 59
[SENSe:]EVENt:PSUMmary:EDGE?
Returns the status of the edge events for ALL ports.
Parameters None
Comments The value returned is in the range of +0 to +15 and is the sum of the following
values:
This command is similar to the [SENSe:]EVENt:PORTn:EDGe? command
except that this command returns the status for all ports.
Example If the EVEN:PSUM:EDGE? command returns a value of 10 it indicates an edge event
occurred on Ports 1 and 3 (values 2 and 8 respectively, see table).
Value Returned Meaning
0 No Edge Event occurred in any port
1 An Edge event occurred in Port 0
2 An Edge vent occurred in Port 1
4 An Edge vent occurred in Port 2
8 An Edge vent occurred in Port 3