Vue de la page 19
10
Setting the Interfaces
Setting Wander Transmit Interface
6 Choose the WANDER MASK setting required.
You can choose the wander modulating frequency and wander
amplitude if is chosen.
If you choose , you can choose the "spot" wander frequency. The
wanderamplitudeisadjustedandcontrolled accordingto yourwander
frequency choice.
SONET Wander (STS-3, OC-3, OC-12, OC-48)
7 Set up the SONET transmit interface. See “Setting SONET Transmit
Interface” page 4.
8 Choose JITTER/WANDER .
If you wish to add jitter to the SONET signal, see "Setting Jitter
Transmit Interface " page 7.
9 Choose WANDER .
10 Choose the WANDER MASK setting required.
You can choose the wander modulating frequency and wander
amplitude if is chosen.
If you choose , you can choose the "spot" wander frequency. The
wanderamplitudeisadjustedandcontrolled accordingto yourwander
frequency choice.
OFF
SPOT
WANDER
ON
OFF
SPOT
Vue de la page 19