XStreamPKGE™EthernetRFModemProductManualv5.x00[2006.02.24]
CN (Exit AT Command Mode) Command
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
<Command Mode Options> CN Command is used
to explicitly exit AT Command Mode.
CO (DO3 Timeout) Command
AT Command: ATCO
Binary Command: 0x2F (47 decimal)
Parameter Range: 0 – 0xFFFF [x 1 second]
Default Parameter Value: 3
Number of bytes returned: 2
Related Commands: CD (DO3 Configuration),
DR (DI3 Configuration)
Minimum Firmware Version Required: 4.30
<Serial Interfacing> DO3 (Data Output 3) output
will return to default after no DI3 (Data Input 3)
status information is received during the timeout
period.
Use with CD = 1 or 2, DR = 1.
CS (DO2 Configuration) Command
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range: 0 – 4
Parameter Configuration
0 RS-232
flow control
1 RS-485 TX enable low
2 high
3 RS-485 TX enable high
4 low
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: RT (DI2 Configuration),
TO (DO2 Timeout)
Minimum Firmware Version Required: 4.27D
<Serial Interfacing> CS Command is used to
select the behavior of the DO2 pin signal. This
output can provide RS-232 flow control, control
the TX enable signal (for RS-485 or RS-422
operations), or set the default level for the I/O
line passing function.
By default, DO2 provides RS-232
(Clear-to-
Send) flow control.
CT (Command Mode Timeout) Command
<Command Mode Options> CT Command sets
the amount of time before AT Command Mode
terminates automatically. After a CT time of
inactivity, the modem exits AT Command Mode
and returns to Idle Mode. AT Command Mode can
also be exited manually using CN (Exit AT
Command Mode) Command.
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
Parameter Range: 0x02 – 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0xC8 (200 decimal,
20 seconds)
Number of bytes returned: 2
DC (Disconnect) Command
AT Command: ATDC
Binary Command: 0x37 (55 decimal)
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
MD (RF Mode)
Minimum Firmware Version Required: 4.30
<Networking & Security> DC Command is used
(when in Multi-Streaming Mode (MD = 1 or 2))
to explicitly force the disconnection of an active
exclusive connection. If MD = 1, the base
modem will force the disconnection of an
exclusive connection. If MD = 2, the remote
modem will send a “Disconnect Request Packet”
to the base modem.
©2006MaxStream,Inc.ConfidentialandProprietary 26