XStreamPKGE™EthernetRFModemProductManualv5.x00[2006.02.24]
FH (Force Wake-up Initializer) Command
AT Command: ATFH
Binary Command: 0x0D (13 decimal)
<Sleep (Low Power)> FH Command is used to
force a Wake-up Initializer to be sent on the next
transmit. WR (Write) Command does not need to
be issued with FH Command.
Use only with cyclic sleep modes active on remote modems.
FL (Software Flow Control) Command
AT Command: ATFL
Binary Command: 0x07 (7 decimal)
Parameter Range: 0 – 1
Parameter Configuration
0
<Serial Interfacing> FL Command is used to
configure software flow control. Hardware flow
control is implemented with the XStream Modem
as the DO2 pin (
), which regulates when
serial data can be transferred to the modem. FL
Command can be used to allow software flow
control to also be enabled. XON character used is
0x11 (17 decimal). XOFF character used is 0x13
(19 decimal).
Disable software
flow control
1
Enable software
flow control
Default Parameter Value: 0
Number of bytes returned: 1
FT (Flow Control Threshold) Command
AT Command: ATFT
Binary Command: 0x24 (36 decimal)
Parameter Range: 0 – (Receiving modem DO
buffer size minus 0x11 bytes)
Default Parameter Value: Receiving modem DO
Buffer size minus 0x11
Number of bytes returned: 2
Minimum Firmware Version Required: 4.27B
<Serial Interfacing> Set/Read the flow control
threshold. When FT bytes have accumulated in
the DI buffer,
is de-asserted or the XOFF
software flow control character is transmitted.
GD (Receive Good Count) Command
AT Command: ATGD
Binary Command: 0x10 (16 decimal)
Parameter Range: 0 – 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: ER (Receive Error Count)
<Diagnostics> Set/Read the count of good
received RF packets. Parameter value is reset to
0 after every reset and is not non-volatile (Value
does not persist in the modem’s memory after a
power-up sequence). Once the “Receive Good
Count” reaches its maximum value (up to
0xFFFF), it remains at its maximum count value
until the maximum count value is manually
changed or the modem is reset.
HP (Hopping Channel) Command
AT Command: ATHP
Binary Command: 0x11 (17 decimal)
Parameter Range: 0 – 6
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: DT (Destination Address),
ID (Modem VID), MK (Address Mask)
<Networking> HP Command is used to set the
modem’s hopping channel number. A channel is
one of three layers of addressing available to the
XStream modem. In order for modems to
communicate with each other, the modems must
have the same channel number since each
network uses a different hopping sequence.
Different channels can be used to prevent
modems in one network from listening to
transmissions of another.
©2006MaxStream,Inc.ConfidentialandProprietary 28