5-20 Diagnostic Tests
101 EIGS/MIGS Board Test
1 Select: 101
2 Press: READY to run the test.
3 If an error is found:
The error code appears.
Look up the code in “Error Code/TAG Cross-Reference” on page 2-3 to determine
which TAG to follow.
Power-on-reset to exit.
4 If no errors are found:
The test continues to run.
After about five minutes, press STOP to exit.
102 EIGS/MIGS Board Test (Continuous Loop)
1 Go to: 102
2 Press: READY to run the test.
3 If an error is found:
The error code is displayed for at least 1 second.
Look up the code in “Error Code/TAG Cross-Reference” on page 2-3 to determine
which TAG to follow.
If the test resumes, press STOP to exit; if the test does not resume, power-on-reset.
4 If no errors are found:
The test continues to loop.
Press STOP to exit.