Vue de la page 255
Appendix D - CLI Reference
256
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01
Where:
group-number Indicates the RAID group ID. The valid range of values
is 0-15, inclusively.
id Indicates the physical VIMM ID. The valid range of
values is 0-83, inclusively.
state Indicates the state of each VIMM in the 5-VIMM
RAID group. Valid values are:
data—VIMM is being used for data, either user data or
parity data.
REBUILDING—VIMM is currently being rebuilt by the
RAID engine to recover from a prior failure.
FAULT—A fault has occurred for this VIMM. If a spare is
available, a rebuild occurs for this virtual VIMM.