HP NonStop Shadowbase Command Definitions
Consumer Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
140
This is the network IP address (e.g., 34.35.0.132) or DNS name of the
backup server. In combination with the NETBACKUPPORT value, below,
it identifies a specific TCP/IP socket that receives the data. If a DNS name
is used, and the DNS entry has multiple IP addresses associated with it, a
message is output to EMS and the first address returned is used.
NETBACKUPPORT portnumber
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.600 None 1 65535 No
Client Server Extended Open Target
This identifies the port on the NETBACKUPADDRESS to use for the
TCP/IP socket. There is no default value. The minimum value is 1 and
the maximum value is 65535. The
NETBACKUPADDRESS/NETBACKUPPORT combination must be unique
for each Consumer. It must match the NETWORK PORT parameter
entered in the HP Shadowbase Other Servers configuration on the backup
server.
NETBACKUPPROCESS netprocessname
Initial Changed
Version Version Values Default Value Specifications Alter
3.600 $ZTC0 Valid NSK TCP/IP process name No
Client Server Extended Open Target
This identifies the name of the backup HP NonStop network process for
the TCP/IP environment.
NETBUFFERS num
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.500 2 1 32 No
Client Server Extended Open Target
The number of message blocks to be allocated by the Consumer for use
in communication with the target process (target Consumer, HP
Shadowbase Other Servers, etc). Each message from the Consumer to
the target process is replied to with an acknowledgement, up to
NETBUFFERS messages can be waiting for an acknowledgement, or
“outstanding”, at a time. The minimum value is 1. The maximum is 32.
The default value is 2.
Setting the value to 1 defines synchronous communication and the
Consumer will wait for an acknowledgement from the target process
before sending the next message. A value of 2 or more defines