Hp Linux Server Management Software Manuel d'utilisateur Page 48

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 47
Toolkit utilities 48
DriveType
The value that you enter for this option specifies the type of drive (SAS, SATA, or parallel SCSI) that ACU must
use to build the array.
OnlineSpare
The value for this option determines whether the array specified previously in the script will be configured
with spare drives.
Method mode Possible values Default value
Custom
To specify exactly which drives to use as spares,
use the applicable convention (port:ID, box:bay,
or port:box:bay).
To specify only the number of spares (not the
exact IDs), enter that number as the value for
this
option. ACU automatically selects only those
drives that are suitable for the array.
To specify that the array should not have spares,
enter
None
.
In Configure action mode: None
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that are
already present in the configuration
Auto
Yes (indicating one spare)
No
In Configure action mode: Yes
(indicating one spare)
In Reconfigure action mode, ACU
ignores any value entered for this
option and keeps any spares that are
already present in the configuration
Logical Drive category
The Logical Drive category has the following options:
ArrayAccelerator (on page 48)
LogicalDrive (on page 49)
LogicalDriveSSPState (on page 49)
ParityGroups (on page 49)
PreferredPath (on page 49)
RAID (on page 49)
Sectors (on page 50)
Size (on page 50)
SSPAdaptersWithAccess (on page 50)
StripeSize (on page 50)
ArrayAccelerator
This option specifies whether the array accelerator is enabled or disabled for the specified logical drive. The
default value is Enabled.
Vue de la page 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 71 72

Commentaires sur ces manuels

Pas de commentaire