SENTRY Users Guide Section 2 - 13
Fitzgerald & Long
8. Command - This field normally defines the startup UNIX shell the user invokes. The System Profile
provides a “default. If you wish to use the default you need only press <RETURN>. Otherwise, enter the
path to the UNIX shell you wish this user to invoke at startup.
9. Groups - This field is multi-valued and lists the users supplementary groups. The GID for each
group is displayed along with the group name in parentheses. Some systems allow only 8 simultaneous
supplementary groups. Take care that you plan your group memberships carefully so that you do not need
to exceed this limit.
At this prompt you may enter a new group name, an existing group name, a @for a list of existing
groups and their GIDs, or a @followed by part of a group name to see a cross reference list by group
name.
Enter field number, “C”ustom, “F”ile, “DEL”ete or <ESC> to exit - This is the standard
modifications prompt for the User Maintenance program. You may access any field by entering the
number to the left of the field, such as 2for the Department field prompt.
SUN
Custom User Data Maintenance
08/16/00
User : peggy
1: Minimum password change (days) : 5
2: Maximum password change (days) : 90
3: Password change warning (days) : 5
4: Maximum inactive time (days) : 21
5: Expiration date (MM/DD/YY) : 12/31/00
Enter field number, "F"ile or "<ESC>" to exit :
Figure 15 - This is an example of the ”Custom User Data Maintenancedata entry screen.
To execute this program, enter 2.” User Maintenance from the Main Sentry menu, after recalling an
exiting user or entering a new user you may enter Cat the bottom prompt. Entering Cinvokes this
program. The following paragraphs describe the five available options.
1. Minimum password change (days): Enter the number of days before a user is allowed to change
his existing password. For example, if UNIX has just expired a users password and the user enters a new
one, you can use this parameter to prevent the user from resetting his password to the old one for the
number of days you specify. The idea is that if the user is forced to keep the new password for several
days, he will not change it back to the older one. We recommend 5 days.
2. Maximum password change (days): Enter the number of days before a user is forced by UNIX
to change his password. Many companies use 90 days as a standard. This would allow a user to keep a
Vue de la page 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 112 113

Commentaires sur ces manuels

Pas de commentaire

Tripp Lite SU6000RT3UHVXL podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Zasilacze bezprzerwowe (UPS) Tripp Lite SU6000RT3UHVXL.
Dostarczamy 1 pdf podręczników Tripp Lite SU6000RT3UHVXL do pobrania za darmo według typów dokumentów: Arkusz Danych






Więcej produktów i instrukcji dla Zasilacze bezprzerwowe (UPS) Tripp Lite

Modele Rodzaj dokumentu
SU3000RTXLCD3U Arkusz Danych   Tripp Lite SmartOnline 100-127V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial, 6 strony
SU1000XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 6 strony
SU2200XLCD Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, LCD display, USB, DB9 Serial, 7 strony
SU2200RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 2.2kVA 1.8kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
SU1000RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1kVA 900W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 6 strony
SU10KRT3/1X Arkusz Danych   Tripp Lite SmartOnline 3-Phase In/1-Phase Out 200-240V 10kVA 7kW On-Line, Double-Conversion UPS, Extended Run, SNMP, Webcard pre-installed, 6U Rack/Tower, USB, DB9 Serial, 5 strony
SMART2200RMXL2UP Arkusz Danych   Tripp Lite 2200 VA UPS, 6 strony
SM5000RT3UTAA Arkusz Danych   Tripp Lite SM5000RT3UTAA uninterruptible power supply (UPS), 6 strony
SMART1050SLTAA Arkusz Danych   Tripp Lite SMART1050SLTAA uninterruptible power supply (UPS), 6 strony
SMX3000RT2UTAA Arkusz Danych   Tripp Lite SMX3000RT2UTAA uninterruptible power supply (UPS), 6 strony
SU1500RTXLCD2U Arkusz Danych   Tripp Lite SmartOnline 100-127V 1.5kVA 1.35kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD display, USB, DB9 Serial, 7 strony
HT-RL15UPS Arkusz Danych   Tripp Lite HTRL15UPS, 5 strony
SU16KRTHW Arkusz Danych   Tripp Lite SmartOnline 200-240V, 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU5000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 208/120V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, USB, DB9 Serial, 6 strony
SU12000RT4UHW Arkusz Danych   Tripp Lite SmartOnline 240/120V or 208/120V 12kVA 8.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U, USB, DB9 Serial, Hardwire, 6 strony
SU20KX Arkusz Danych   Tripp Lite SmartOnline 20kVA 16kW Modular 3-Phase UPS System, On-line Double-Conversion UPS, SNMP, Webcard, DB9 Serial, 5 strony
SU6000RT4UTF Arkusz Danych   Tripp Lite SmartOnline 240/208/120V 6kVA 5.4kW On-Line Double-Conversion UPS, Low-Voltage Transformer, Extended Run, SNMP, Webcard, 6U Rack/Tower, Bypass Switch, 7 strony
SU6000RT4UHVHW Arkusz Danych   Tripp Lite SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU3000RTXR3UHW Arkusz Danych   Tripp Lite SmartOnline 110-120V 3kVA 2.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial, Hardwire, 6 strony
SU40K Arkusz Danych   Tripp Lite SU40K uninterruptible power supply (UPS), 6 strony