Hp 3000 Enterprise Virtual Array Manuel d'utilisateur Page 126

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 236
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 125
Installing the Device Mapper Multipath Enablement Kit
To install the kit, follow the steps described in the Installation and Reference Guide Device Mapper
Multipath Enablement Kit for HP StorageWorks Disk Arrays:
http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?swItem=co-58129-1&
lang=en&cc=us&idx=1&mode=4&
iSCSI Initiator timeout settings for Red Hat 4 and SUSE 9 systems
To define the iSCSI Initiator timeout settings for Red Hat 4 and SUSE 9 systems, move the /etc/
iscsi.conf file to the Session Timeout Settings section and modify as follows:
ConnFailTimeout=5
iSCSI Initiator timeout settings for Red Hat 5 and SUSE 10 systems
To define the iSCSI Initiator timeout settings for Red Hat 5 and SUSE 10 systems, modify either the /
etc/iscsi/iscsid.conf or the /etc/iscsid.conf line as follows:
node.session.timeo.replacement_timeout=5
HPDM Multipath restrictions
HPDM Multipath has the following restrictions:
HPDM Multipath does not provide an auto-failback feature for devices presented through iSCSI
Initiators. HP recommends running the following commands to recover the failed paths and make
them available for I/O failback (a quiesce of I/O is necessary; a reboot also may be required):
# /etc/init.d/iscsi restart or # /etc/init.d/open-iscsi restart
# /sbin/multipath –v3
No clustering support
If Device Mapper Multipath is configured on iSCSI devices (on hosts running SLES OS), the system
may hang during reboot. To avoid this, HP highly recommends running the following command
before rebooting the system:
# /sbin/multipath –F
Setting up the iSCSI Initiator for multipathing126
Vue de la page 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 235 236

Commentaires sur ces manuels