Storage System Hardware Components
106 Enterprise Virtual Array 3000 User Guide
7. When all error conditions have been displayed, press and release the bottom
pushbutton to return to the Er display.
Figure 46: Displaying error condition values
Analyzing Condition Reports
Analyzing each error condition report involves three steps:
1. Identifying the element.
2. Determining the major problem.
3. Defining additional problem information.
See “EMU Generated Condition Reports” on page 161 for details on performing
these tasks.
1 Press & hold top pushbutton to view first error in queue.
2 Press & release top pushbutton.
3 Press & hold top pushbutton to view next error.
4 Press and release the bottom pushbutton at any time to return to the
Er
display.
e.t. = element type, en. = element number, ec = error code
Er
en.
ec
e.t.
en.
ec
e.t.
CXO8233A
3 3 3
1
4
2
2 2
2 2
Vue de la page 105