EMU Generated Condition Reports
186 Enterprise Virtual Array 3000 User Guide
8.7.en.01 CRITICAL ConditionI/O Module Unsupported
The I/O module Fibre Channel link speed is not supported by the backplane. This
error prevents the controller from establishing a link with enclosure drives and
eliminates the enclosure dual-loop capability. This condition report remains active
until the problem is corrected.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
8.7.en.02 CRITICAL ConditionI/O Module Communication
The I/O module is unable to communicate with the EMU.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Contact your HP authorized service representative.
Note: Multiple erroneous error messages indicating I2C bus errors, such as NVRAM
errors, blowers missing, and so forth, could indicate an EMU problem.
8.7.en.10 NONCRITICAL ConditionI/O Module NVRAM Read
An invalid NVRAM read occurred and automatic recover was initiated.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Observe the I/O module status LEDs for an operational display.
3. Contact your HP authorized service representative.
8.7.en.11 NONCRITICAL ConditionI/O Module NVRAM Write
The system is unable to write data to the I/O module NVRAM.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Observe the I/O module status LEDs for an operational display.
3. Contact your HP authorized service representative.