Hp 3Gb SAS Switch for HP BladeSystem c-Class Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
Zoned storagesingle domain, standard cabling
This example illustrates standard cabling for a single-domain configuration using single-port SATA
disk drives. In this configuration, note the following:
One cable from each MDS600 I/O module to the switch offers single-domain connectivity.
Devices and quantities
MDS600 storage enclosures: 1
MDS600 I/O modules: 2
BladeSystem c7000 enclosures: 1
3Gb SAS BL switches: 1
Server blade types: half-height and full-height
Connection details
Switch in interconnect bay 5:
Port 1: to MDS600 drawer 2, primary
I/O module, port 1
Port 5: to MDS600 drawer 1, primary
I/O module, port 1
Notes
If sufficient ports on the switch are avail-
able, HP recommends connecting an ad-
ditional cable from the switch to each
I/O module, for additional performance.
For an example, see Zoned stor-
agedual domain, wide-port
cabling, page 24.
As shown in this illustration, server bays
18 may access MDS600 drawer 2 and
server bays 916 may access MDS600
drawer 1.
Installation procedures22
Vue de la page 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 55 56