46 Connecting to the controller CLI port
If the default user or password—or both—have been changed for security reasons, enter the secure
login credentials instead of the defaults shown above.
7. At the prompt, type the following command to set the values you obtained in step 1 for each network
port, first for controller A and then for controller B:
set network-parameters ip
address
netmask
netmask
gateway
gateway
controller a|b
where:
address
is the IP address of the controller
netmask
is the subnet mask
gateway
is the IP address of the subnet router
a|b specifies the controller whose network parameters you are setting
For example:
# set network-parameters ip 192.168.0.10 netmask 255.255.255.0 gateway
192.168.0.1 controller a
# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway
192.168.0.1 controller b
8. Type the following command to verify the new IP addresses:
show network-parameters
Network parameters, including the IP address, subnet mask, and gateway address are displayed for
each controller.
9. Use the ping command to verify network connectivity.
For example:
# ping 192.168.0.1 (gateway)
Info: Pinging 192.168.0.1 with 4 packets.
Success: Command completed successfully. - The remote computer responded with 4
packets.
10. In the host computer's command window, type the following command to verify connectivity, first for
controller A and then for controller B:
ping controller-
IP-address
If you cannot access your system for at least three minutes after changing the IP address, your network
might require you to restart the Management Controller(s) using the CLI. When you restart a
Management Controller, communication with it is temporarily lost until it successfully restarts.
Type the following command to restart the management controller on both controllers:
restart mc both
11. When you are done using the CLI, exit the emulator.
12. Retain the new IP addresses to access and manage the controllers, using either the SMU or the CLI.
NOTE: Using HyperTerminal with the CLI on a Microsoft Windows host:
On a host computer connected to a controller module’s mini-USB CLI port, incorrect command syntax in a
HyperTerminal session can cause the CLI to hang. To avoid this problem, use correct syntax, use a different
terminal emulator, or connect to the CLI using telnet rather than the mini-USB cable.
Be sure to close the HyperTerminal session before shutting down the controller or restarting its Management
Controller. Otherwise, the host’s CPU cycles may rise unacceptably.
NOTE: When using the USB port of a personal computer or laptop connected to the server to initially
configure the MSA 2040 array, some computers or laptops may not properly connect to the array. If so,
access and configure the MSA storage system using the MSA Device Discovery Tool for Windows.
The Device Discovery Tool discovers MSA storage devices in the network, in the local subnet, and directly
attached to the server. The MSA Device Discovery Tool for Windows is available as a software download.
Vue de la page 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 93 94

Commentaires sur ces manuels

Pas de commentaire