HP StorageWorks
Storage Mirroring Reporting Center user guide
Part number: T2558-96071
First edition: February 2008
Vue de la page 0
1 2 3 4 5 6 ... 49 50

Résumé du contenu

Page 1 - HP StorageWorks

HP StorageWorksStorage Mirroring Reporting Center user guidePart number: T2558-96071First edition: February 2008

Page 2

10NOTE: Storage Mirroring only needs to be installed on the servers for which you want to collect data. The collection server should NOT be running St

Page 3 - Contents

Storage Mirroring Reporting Center user guide 11For help troubleshooting connectivity issues related to invalid permissions, see “Storage Mirroring Re

Page 4

123. In the Server Properties dialog box, enter the hostname of the server you wish to monitor in the Name field. Optionally, add a description for th

Page 5

Storage Mirroring Reporting Center user guide 13•“Unassigning a group” on page 16•“Deleting a group” on page 16• “Configuring alerts” on page 17• “Con

Page 6

14Storage Mirroring data collectionBy default, Storage Mirroring data is collected at the following frequencies:If the values for a data point have no

Page 7 - About this guide

Storage Mirroring Reporting Center user guide 15You may need to add alternative names as aliases to the node definition for Storage Mirroring servers.

Page 8 - Documentation feedback

163. Edit the node.4. Click OK.Deleting nodesUnassigning a node does not delete it from Storage Mirroring Reporting Center. To delete a node, you must

Page 9 - Requirements

Storage Mirroring Reporting Center user guide 17Configuring alertsYou can set up Storage Mirroring Reporting Center to monitor Storage Mirroring serve

Page 10 - Permissions

18• “Running reports” on page 18•“Selecting a time period” on page 19•“Selecting a node” on page 19•“Selecting a report” on page 19•“Drilling down” on

Page 11 - Getting started

Storage Mirroring Reporting Center user guide 19• “Printing reports” on page 20• “Saving reports” on page 20• “Emailing reports” on page 21You can run

Page 12 - Viewing alerts

Legal and notice information© Copyright 2008 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with regar

Page 13 - Configuring system settings

20• “Opening dashboard reports” on page 20• “Drilling down within detailed tables” on page 20• “Displaying previous reports” on page 20Trend chart dri

Page 14 - Configuring nodes

Storage Mirroring Reporting Center user guide 213. Click Save.Emailing reportsYou can send reports as emails by specifying details in the Mail dialog

Page 15 - Creating nodes

22• “SMRC reports” on page 33•“Data collection errors” on page 33•“Alerts” on page 33Dashboard reportsDashboard reports include the following:• “Serve

Page 16 - Configuring groups

Storage Mirroring Reporting Center user guide 23The information returned by this report includes:•Server—The name of the server•Interface—The identifi

Page 17 - Configuring views

24• Repset—The name of the replication set•Protected Time—The percentage of time the data was protected•Unprotected Time—The percentage of time the da

Page 18

Storage Mirroring Reporting Center user guide 25Server performanceThe Server Performance Dashboard displays the monitor status, status queue performan

Page 19 - Drilling down

26• Memory Queue—Bytes in memory queue programmatically calculated by adding mirror + replication - disk queueStorage Mirroring transmission reportThe

Page 20 - Saving reports

Storage Mirroring Reporting Center user guide 27Storage Mirroring server connectionsThe Storage Mirroring Server Connections report provides a list of

Page 21 - Emailing reports

28To run the Network Interface Configuration report, select the Storage Mirroring node in the tree. Right-click and select Configuration Reports, Netw

Page 22 - Dashboard reports

Storage Mirroring Reporting Center user guide 29To run the Connection Status report, select a Storage Mirroring server in the tree. Right-click and se

Page 23 - Connections

Storage Mirroring Reporting Center user’s guide iiiAbout this guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - Transmission

30• Target IP Address- The address of the target serverFile system detailsThe File System Details report displays information on the configuration and

Page 25 - Server performance

Storage Mirroring Reporting Center user guide 31• Target IP Address—The address of the target server•Mirror Queue—Bytes in mirror queue•Replication Qu

Page 26 - Configuration reports

32• “Processor utilization” on page 32NOTE: Reports are customizable, so not all available data may be visible in a particular report view.File system

Page 27 - Network interface details

Storage Mirroring Reporting Center user guide 33The following information is returned by this report:•Server—The name of the server•CPU Utilization—Th

Page 28 - Status reports

34Each report type has certain associated parameters that you can customize. Hovering over a button displays the name of the parameter. To customize a

Page 29 - Protected time

Storage Mirroring Reporting Center user guide 353. Click OK.Report filterThe Report Filter allows you to filter the data in a report result using cond

Page 30 - Performance reports

36the Backup Save Set Size field contains information on the size of a backup Save Set. The data is measured in megabytes. By default, a table report

Page 31 - Utilization reports

Storage Mirroring Reporting Center user guide 3712. You can add multiple style rules to the list of style rules so that rules are matched against the

Page 32 - Processor utilization

38• Trend• Area• Bar• PieBy default, charts display the legend if there is enough space to display it without significantly affecting the size of the

Page 33 - Customizing report appearance

Storage Mirroring Reporting Center user guide 39SeriesAll chart based reports provide the ability to select which series are displayed in the report.

Page 34 - Title parameter

ivServer utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Pro

Page 35 - Report filter

403. Specify which data series should be plotted on this data view. If you have multiple data views, you can move the series to the second data view b

Page 36 - Cell styles

Storage Mirroring Reporting Center user guide 41x-axisThe x-axis parameter is only available when configuring stacked bar charts. Use the x-axis param

Page 37 - Legend option

423D surface chart and 3D bar chart appearance parameters3D Surface and Bar charts allow you to plot a data series in three dimensions. To do this, th

Page 38 - Chart labels

Storage Mirroring Reporting Center user guide 43• Field—Field to plot.•Unit—Unit of the selected field.•Scale To—The multiplier the field is scaled to

Page 39 - Data views

443. In the Value Type field, specify whether the value is a fixed static value or something that is determined at the time the report is evaluated. T

Page 40 - Three-dimensional bar options

Storage Mirroring Reporting Center user guide 45Chart style editorThe chart style editor allows editing of the colors and fonts of different chart ele

Page 41 - Pie 3D options

46• For configuration information, look for controller.xml in the Storage Mirroring Reporting Center install path, and all .xml files in the install s

Page 42 - Rotation

Storage Mirroring Reporting Center user guide 47Removing non-Storage Mirroring nodesStorage Mirroring Reporting Center is designed to monitor Storage

Page 43 - Condition

48If the collector errors report does not indicate what the problem is, proceed to look at the log files. For more information, see “Changing log leve

Page 44 - Conditions

Storage Mirroring Reporting Center user guide 49</AXMLRESULT>Verifying WMI connectivityTo test WMI connectivity from a Storage Mirroring Reporti

Page 45

Storage Mirroring Reporting Center user’s guide vTrend chart specific appearance parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 48 - Sample output

Storage Mirroring Reporting Center user guide 7About this guideThis document describes how to use the Storage Mirroring® Reporting Center interface to

Page 49 - Verifying WMI connectivity

8• Applicable error messages• Operating system type and revision level• Detailed, specific questionsFor continuous quality improvement, calls may be r

Page 50

Storage Mirroring Reporting Center user guide 9Storage Mirroring Reporting Center overviewStorage Mirroring Reporting Center (SMRC) is a centralized r