Troubleshooting 89
00 Array Controller Firmware Ver <version>
Type: Informational
Description: Displays the current version of the firmware running on the
controller.
Action: None
01 HP MSA500-G2 Startup Complete
Type: Informational
Description: The controller completed its power up sequence and is now
operational.
Action: None
02 Enable Volume <n>? '<'=NO, '>'=YES
Type: User Input
Description: An issue exists with a configured volume that may result in data
loss. Refer to display messages for more information.
Action:
Selecting NO or not selecting any option within the timeout period causes
the controller to disable the volume, so the user can attempt to fix the issue.
Selecting YES causes the controller to enable the volume regardless of the
issue.
03 Critical Lock-Up Detected. Code=<n>h
Type: Error