Hp XP Application Performance Extender Software Manuel d'utilisateur Page 107

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 120
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 106
C Deployment scenarios
Application level SLOs
SAN configuration
Two HP-UX 11.31 servers connected to an XP24000 HP disk array through a Fibre Channel fabric
Server 1 HP-UX 11.31 server (hp1) with an instance of Oracle 11g (workload1) configured on
the XP24000 array on a Disk Group 1
Server 2 HP-UX 11.31 server (hp2) running a backup I/O workload (workload 2) to a different
Disk Group 2 on the XP24000 array
hp1 has miscellaneous applications with low workloads (workload set 3) to Disk group 3
hp2 has miscellaneous applications with low workloads (workload set 4) to Disk group 4
SLO requirements
Latency goal of 20 milliseconds for workload 1 most critical application
Bandwidth goal of 200 MBps for workload 2
No specific goal for workload set 3 and 4
P9000 Application Performance Extender SLO configuration steps:
NOTE:
During installation, the controller may be setup on hp2.
1. On hp1, associate workload 1 to a PRM Group prmg-wl1.
2. On hp2, associate workload 2 to a PRM Group prmg-wl2.
3. Create an SLO profile with the four workloads (1, 2, 3, and 4), and assign the profile to an array.
4. Monitor the performance of the four workloads latency or bandwidth based on the desired
SLO type.
NOTE:
The controller can be in the monitor state to enable the user to monitor the workload performance
without an active SLO assignment.
5. Enable the controller.
6. Monitor the performance of all four workloads.
7. Modify the SLO profile and assign the profile to an array.
Host level SLOs
SAN configuration
HP StorageWorks P9000 Application Performance Extender Software User Guide 107
Vue de la page 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 119 120

Commentaires sur ces manuels

Pas de commentaire