Max.: Indicates the maximum transfer rate for the specified period.
Response Time: This column indicates the time for replying from the LU path when I/O accesses
are made from the host to the LU path. The unit is milliseconds. The average response time in the
period specified at Monitoring Term is displayed.
This column displays a hyphen (-) if the I/O rate is 0 (zero).
Monitoring Paths between Host Bus Adapters and Ports
If XP Performance Control is enabled, Performance Monitor can be used to monitor paths between
host bus adapters (HBAs) in host servers and ports on the storage system. HBAs are contained in host
servers and serve as ports for connecting the host servers to the storage system. This section describes
how to view I/O rates and transfer rates between host bus HBAs and ports.
Before taking the steps described in the following sections, you need to perform following operations:
1. Perform an XP Performance Control operation (see the HP StorageWorks XP24000/XP20000
Performance Control User Guide).
2. Start the monitoring by Performance Monitor in accordance with the procedure described in
Starting and Stopping Storage System Monitoring on page 60 and obtain the traffic data
between host bus HBAs and ports.
Viewing HBA Information
Viewing I/O Rates between HBAs
Performance Monitor monitors traffic between HBAs in the hosts and ports on the storage system, and
measures I/O rates (that is, the number of disk I/Os per second).
To view I/O rates:
1. Ensure that the Auto LUN window is displayed.
2. Click the WWN tab).
The tree displays a list of XP Performance Control groups ( ). Below that list, an item named
Not Grouped.
To display host bus adapters ( ) in the XP Performance Control group, double-click an XP
Performance Control group.
To display host bus adapters ( ) that do not belong to any XP Performance Control group,
double-click Not Grouped.
3. Select IOPS from the list on the right side of the window.
4. In Monitoring Term, do one of the following:
To view the I/O rate in real time, you must select the Real Time option, specify the number
of recent collections of statistics which should be displayed in the graph, and then click Apply.
To view I/O rates for a certain period of time in the last 24 hours, you must select the From
option, change the date and time in the From and To boxes, and then click Apply. Use the
arrow button and the sliders when you change the date and time in the From and To boxes.
For details on the Real Time option and the From option, see WWN Tab of the Performance
Monitor Window on page 49.
5. In the tree, do one of the following:
To view the I/O rate for host bus adapters in an XP Performance Control group, select the XP
Performance Control group.
Performance Monitor Operations92
Vue de la page 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 171 172

Commentaires sur ces manuels

Pas de commentaire

MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Do samochodu MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2.
Dostarczamy 1 pdf podręczników MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2 do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Spis treści

MODEL DCA150USJ2

1

PROPOSITION 65 WARNING

2

REPORTING SAFETY DEFECTS

3

DCA150USJ2 60 Hz

4

Generator

4

PARTS ORDERING PROCEDURES

5

SAFETY INFORMATION

10

SPECIFICATIONS

12

DIMENSIONS

13

INSTALLATION

14

GENERAL INFORMATION

16

MAJOR COMPONENTS

17

DIAGNOSTIC DISPLAY

18

USE DEFAULTS

28

CUSTOM SETUP

28

AUTOMATIC SCAN OFF

28

SOFTWARE

32

MURPHY: X.XX

32

INCREASE

35

ENGINE OPERATING PANEL

37



38



39



39



40

Over Current Relay

40

LOAD APPLICATION

41



42



42

Generator Amperage

42



43



43

AC Ammeter Gauge Reading

43



44

INSPECTION/SETUP

46

GENERATOR START-UP PROCEDURE

50



52



52

MAINTENANCE

53

TRAILER MAINTENANCE

56

TRAILER WIRING DIAGRAM

60

GENERATOR WIRING DIAGRAM

61

ENGINE WIRING DIAGRAM

62

TROUBLESHOOTING (GENERATOR)

63



65

SAMPLE PARTS LIST

66

NO. Column

66

PART NO. Column

66

QTY. Column

66

REMARKS Column

66

SUGGESTED SPARE PARTS

67

GENERATOR ASSY

68

CONTROL BOX ASSY

70

ENGINE AND RADIATOR ASSY

74

OUTPUT TERMINAL ASSY

78

BATTERY ASSY

80

MUFFLER ASSY

82

FUEL TANK ASSY

84

ENCLOSURE (1) ASSY

86

ENCLOSURE (2) ASSY

90

RUBBER SEALS ASSY

94

NAMEPLATE AND DECALS ASSY

96

HERE’S HOW TO GET HELP

102





Więcej produktów i instrukcji dla Do samochodu MULTIQUIP

Modele Rodzaj dokumentu
Control Box Replacement LS60TD Instrukcja Użytkownika   Multiquip Control Box Replacement LS60TD User Manual, 8 strony
Trash Pump QP3TY Instrukcja Użytkownika   Multiquip Trash Pump QP3TY User Manual, 56 strony
60HZ GENERATOR DCA25SSIU3 Instrukcja Użytkownika   Multiquip 60HZ GENERATOR DCA25SSIU3 User Manual, 76 strony
Tamping Rammer Mikasa MT-86D Instrukcja Użytkownika   Multiquip Tamping Rammer Mikasa MT-86D User Manual, 50 strony