Hp XP Array Manager Software Manuel d'utilisateur Page 82

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 105
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 81
commands can be used to create and split pairs. To enable the system administrator to enter RAID
Manager commands from open-system hosts, you must specify at least one logical device as the command
device. You can also apply command device security to other logical devices in the storage system.
Notes
: If a storage system is divided into SLPRs, and you want to prevent RAID Manager commands from
affecting multiple SLPRs, you must apply command device security to the logical volumes.
Specifying Logical Devices as Command Devices
To enable the system administrator to execute RAID Manager commands from an open-system host, you
must select at least one logical device that will not be manipulated by Continuous Access or Business
Copy, and then specify the device as the command device. When an RAID Manager command is issued
from a host, the command is received by the command device. The command device transfers the
command to a
nother logical device. Then, the command performs an Continuous Access or Business
Copy operation on that logical device.
To specify a logical device as a command device:
1. Start LUN Manager and display the LUN Manager window (Figure 4 on page 21).
2. In the uppe
r-right LU Path list or the lower-right LDEV list, select and right-click the desired
logical device.
Notes
:
If nothing
is displayed in the LU Path list, select a host group
in the tree.
•The icons
and indicate command devices.
•The icon
indicates no logical device.
3. From the pop-up menu, select Command Device: Disable -> Enable.
A message appears, asking if you want to use the logical device as a command device.
4. Click the YES button to close the message.
5. Click the Apply button in the LUN Manager window.
A message appears and asks if you want to apply the setting to the storage system.
6. Click the OK button to close the message.
The settings are applied to the storage system.
Deleting Command Devices
To delete a command device:
1. Start LU
N Manager and display the LUN Manager window (Figure 4 on page 21).
2. In the upper-right LU Path list or the lower-right LDEV list, select and right-click a command
device (
or ).
3. From the pop-up menu, select Command Device: Enable -> Disable.
A message appears.
4. Click the YES button to close the message.
5. Click the Apply button in the LUN Manager window.
A message appears and asks if you want to apply the setting to the storage system.
6. Click the OK button to close the message.
The settings are applied to the storage system.
Enabling Command Device Security
To protect logical volumes from RAID Manager commands, you must apply command device security to
the logical volumes. If command device security is applied to a logical device, the logical device will not
be affected by RAID Manager commands issued via command devices from the hosts.
To apply command device security to a logical device:
1. Star
t LUN Manager and display the LUN Manager window (Figure 4 on page 21).
82
Performing LUN Manager Operations
Vue de la page 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 104 105

Commentaires sur ces manuels

Pas de commentaire

MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Do samochodu MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2.
Dostarczamy 1 pdf podręczników MULTIQUIP MQ Power Whisperwatt 60HZ Generator DCA150USJ2 do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika


Spis treści

MODEL DCA150USJ2

1

PROPOSITION 65 WARNING

2

REPORTING SAFETY DEFECTS

3

DCA150USJ2 60 Hz

4

Generator

4

PARTS ORDERING PROCEDURES

5

SAFETY INFORMATION

10

SPECIFICATIONS

12

DIMENSIONS

13

INSTALLATION

14

GENERAL INFORMATION

16

MAJOR COMPONENTS

17

DIAGNOSTIC DISPLAY

18

USE DEFAULTS

28

CUSTOM SETUP

28

AUTOMATIC SCAN OFF

28

SOFTWARE

32

MURPHY: X.XX

32

INCREASE

35

ENGINE OPERATING PANEL

37



38



39



39



40

Over Current Relay

40

LOAD APPLICATION

41



42



42

Generator Amperage

42



43



43

AC Ammeter Gauge Reading

43



44

INSPECTION/SETUP

46

GENERATOR START-UP PROCEDURE

50



52



52

MAINTENANCE

53

TRAILER MAINTENANCE

56

TRAILER WIRING DIAGRAM

60

GENERATOR WIRING DIAGRAM

61

ENGINE WIRING DIAGRAM

62

TROUBLESHOOTING (GENERATOR)

63



65

SAMPLE PARTS LIST

66

NO. Column

66

PART NO. Column

66

QTY. Column

66

REMARKS Column

66

SUGGESTED SPARE PARTS

67

GENERATOR ASSY

68

CONTROL BOX ASSY

70

ENGINE AND RADIATOR ASSY

74

OUTPUT TERMINAL ASSY

78

BATTERY ASSY

80

MUFFLER ASSY

82

FUEL TANK ASSY

84

ENCLOSURE (1) ASSY

86

ENCLOSURE (2) ASSY

90

RUBBER SEALS ASSY

94

NAMEPLATE AND DECALS ASSY

96

HERE’S HOW TO GET HELP

102





Więcej produktów i instrukcji dla Do samochodu MULTIQUIP

Modele Rodzaj dokumentu
Control Box Replacement LS60TD Instrukcja Użytkownika   Multiquip Control Box Replacement LS60TD User Manual, 8 strony
Trash Pump QP3TY Instrukcja Użytkownika   Multiquip Trash Pump QP3TY User Manual, 56 strony
60HZ GENERATOR DCA25SSIU3 Instrukcja Użytkownika   Multiquip 60HZ GENERATOR DCA25SSIU3 User Manual, 76 strony
Tamping Rammer Mikasa MT-86D Instrukcja Użytkownika   Multiquip Tamping Rammer Mikasa MT-86D User Manual, 50 strony