Troubleshooting
153HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
3075 Drive 1 Eject Failed
(Eject command time-out.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
3076 Drive 2 Eject Failed
(Eject command time-out.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
3077 Drive 3 Eject Fail
(Eject command time-out.)
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP