Hp Smart Storage Administrator Manuel d'utilisateur Page 116

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 127
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 115
Troubleshooting 116
Item RAID 0 RAID 1+0 RAID 5 RAID 6
(ADG)
RAID 1(0)
(ADM)
Alternative name
Striping (no
fault
tolerance)
Mirroring Distributed
Data
Guarding
Advanced
Data
Guarding
Advanced
Data
Mirroring
Formula for number of drives usable
for data (n = total number of drives in
array)
n n/2 n-1 n-2 n/3
Percentage of drive space usable*
100% 50% 67% to 93% 50% to 96% 33%
Minimum number of physical drives
1 2 3 4 3
Tolerates failure of one physical drive
No Yes Yes Yes Yes
Tolerates simultaneous failure of
more than one physical drive
No Only if no
two failed
drives are in
the same
mirrored
pair
No Yes Only if no
three drives
are in the
same mirror
group**
Read performance
High High High High High
Write performance
High Medium Low Low Medium
Relative cost
Low High Medium Medium Very high
*Values for the percentage of drive space usable are calculated with these assumptions: (1) all physical drives in the
array have the same capacity; (2) online spares are not used; (3) no more than 14 physical drives are used per array for
RAID 5; and (4) no more than 56 drives are used with RAID 6 (ADG).
**Mirror groups include the physical drives in each mirror.
Selecting a RAID method
Not all controllers support all RAID levels. To determine the RAID capabilities of your controller, see the
model-specific information for your controller on the HP website
(http://www.hp.com/products/smartarray).
Most important criterion Also important Suggested RAID level
Fault tolerance
Cost effectiveness
I/O performance
RAID 6
RAID 10 (ADM), RAID 1+0, RAID 50, RAID 60
Cost effectiveness
Fault tolerance
I/O performance
RAID 6
RAID 5 (RAID 0 if fault tolerance is not required)
I/O performance
Cost effectiveness
Fault tolerance
RAID 5 (RAID 0 if fault tolerance is not required)
RAID 10 (ADM), RAID 1+0, RAID 50, RAID 60
Alternative fault-tolerance methods
Your operating system may also support software-based RAID or controller duplexing.
Software-based RAID resembles hardware-based RAID, except that the operating system works with
logical drives as if they were physical drives. To protect against data loss caused by physical drive
failure, each logical drive must be in a different array from the others.
Controller duplexing uses two identical controllers with independent, identical sets of drives containing
identical data. In the unlikely event of a controller failure, the remaining controller and drives will service
all requests.
Vue de la page 115