Hp Smart Storage Administrator Manuel d'utilisateur Page 61

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 127
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 60
Operations 61
SSD Over Provisioning Optimization
Access to solid state devices can be optimized by deallocating all used blocks before any data is written to
the drive. The optimization process is performed when the first logical drive in an array is created, and when
a physical drive is used to replace a failed drive. Not all controllers support this option.
This feature is disabled by default in the CLI.
When creating the first logical drive in an array, the ssdoverprovisioningoptimization parameter
specifies to initialize solid state drives supporting the rapid parity initialization feature. The only valid option
is "on".
Example:
ctrl slot=1 create type=ld drives=1I:1:1 ssdoverprovisioningoptimization=on
ctrl slot=1 create type=ld drives=1I:1:2 ssdopo=on
Assigning a chassis name to the controller
If a controller is configured with at least one logical drive, you can give the controller a simplified name (the
chassis name) to make it easier to identify and enter the correct controller in a command.
Syntax:
<target> modify ch="new chassis name"
where <target> is a controller. If you change the chassis name of a controller that you have set as the
default target ("Setting the target" on page 53), you must reset the target.
Example commands:
=> ctrl sn=P56350D9IP903J modify ch="Lab 6"
=> ctrl ch="Lab 4" modify ch="Lab 6"
Managing spare drives
Assigning one or more online spare drives to an array enables you to postpone replacement of faulty drives.
However, it does not increase the fault-tolerance level of any logical drives in the array. For example, a
logical drive in a RAID 5 configuration suffers irretrievable data loss if two of its physical drives are
simultaneously in a failed state, regardless of the number of spare drives assigned to the array.
Any drive that you want to use as a spare must meet the following criteria:
It must be an unassigned drive or a spare for another array.
It must be of the same type as existing drives in the array (for example, SATA or SAS).
It must have a capacity no less than that of the smallest drive in the array.
Syntax:
<target> add spares=[#:]#:#,[#:]#:#,[#:]#:#[#:]#:#,...|allunassigned
[forced]
<target> remove spares=[#:]#:#,[#:]#:#,[#:]#:#[#:]#:#,...|all
where <target> is an array (or logical drive, if the array contains only one logical drive). The forced
parameter represses any warning message prompts. If you specify a drive range, any drives in the range that
do not meet the previous criteria are not used.
Example commands:
=> ctrl slot=3 array B add spares=1:6
Vue de la page 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 126 127

Commentaires sur ces manuels

Pas de commentaire