Testing enclosure connections 27
Testing enclosure connections
NOTE: Once the power-on sequence for enclosures succeeds, the storage system is ready to be
connected to hosts, as described in "Connecting the enclosure to data hosts" (page 31).
Powering on/powering off
Before powering on the enclosure for the first time:
Install all disk drives in the enclosure so the controller can identify and configure them at power-up.
Connect the cables and power cords to the enclosures as explained in the quick start instructions.
NOTE: MSA 2040 controller enclosures and drive enclosures do not have power switches (they are
switchless). They power on when connected to a power source, and they power off when disconnected.
Generally, when powering up, make sure to power up the enclosures and associated data host in the
following order:
•Drive enclosures first
This ensures that disks in each drive enclosure have enough time to completely spin up before being
scanned by the controller modules within the controller enclosure.
While enclosures power up, their LEDs blink. After the LEDs stop blinking
if no LEDs on the front
and back of the enclosure are amber
the power-on sequence is complete, and no faults have been
detected. See "LED descriptions" (page 73) for descriptions of LED behavior.
Controller enclosure next
Depending upon the number and type of disks in the system, it may take several minutes for the
system to become ready.
Data host last (if powered down for maintenance purposes)
TIP: Generally, when powering off, you will reverse the order of steps used for powering on.
Power cycling procedures vary according to the type of power supply unit included with the enclosure. For
controller and drive enclosures configured with the switchless AC power supplies, refer to the procedure
described under AC power supply below. For procedures pertaining to a) controller enclosures configured
with DC power supplies, or b) previously installed drive enclosures featuring power switches, see "DC and
AC power supplies equipped with a power switch" (page 28).
IMPORTANT: See "Power cord requirements" (page 86) and QuickSpecs for more information about
power cords supported by MSA 2040 enclosures.
AC power supply
Enclosures equipped with switchless power supplies rely on the power cord for power cycling. Connecting
the cord from the power supply power cord connector to the appropriate power source facilitates power
on; whereas disconnecting the cord from the power source facilitates power off.