C H A P T E R 2 HP e-Commerce/XML Server Accelerator SA7150 User Guide
12
4. Click the OK button. The COM1 Properties panel appears. Set
the values displayed here to 9600, 8, none, 1, and none.
5. Click the OK button.
Using
HyperTerminal*
If youre using HyperTerminal* you must make the following
configuration change:
1. In the File menu, click Properties.
2. Click the Settings tab.
3. Click the ASCII Setup button.
4. Change the values of Line and Character delay from 0 to at least
1 millisecond.
5. Click OK to exit ASCII Setup.
6. Click OK to exit Connection Properties.
Fail-through
Switch
The Fail-through switch allows you to choose between two options in
the event of a failure. It is located in the opening between the Network
and Server connectors. Use a small screwdriver or paper clip to
operate the switch. The two options are:
Allow traffic to flow through the SA7150 unprocessed. (Fail-
through mode, indicated by a steadily illuminated Inline LED.
Fail-through switch in DOWN position.)
Block traffic flow through the SA7150 entirely. (Fail-safe mode,
indicated by a blinking Inline LED. Fail-through switch in UP
position.)
Please see Appendix B for a description of LED display.