Appendix A Installing the NetServer in an HP Systems Rack
95
2. Install the bezel hinge rack nuts on the left front column (holes 6 and 19
counted up from the base line).
Rack nuts are installed on the rear columns to secure the z-bracket, which is
secured to the NetServer. Use the rack template to locate the mounting holes (see
Figure A-3).
1. Install the z-bracket rack nuts on the right rear column (holes 9 and 13
counted up from the base line).
Install rack nuts at
holes 9 and 13 up
from base line.
Base line
Template
p/n
5064-
5869
Install rack
nuts 11 and
15 holes up
from base
line.
Install rack
nuts at holes
6 and 19 up
from base line.
Figure A-3. Installing Rack Nuts