Switch Command Interface (SWCI)
ServerNet Nomadic Disk (Release 2) User’s Guide523968-001
6-35
Command Execution Error Messages
Cause. The command file file-name is not an EDIT (code 101) file.
Effect. The command is not executed. SWCI waits for the next command.
Recovery. Retry the command with an EDIT file.
Cause. An error occurred during an attempt to open the command file file-name. A
one-line textual description of the type of error encountered follows.
Effect. The command is not executed. SWCI waits for the next command.
Recovery. Retry the command with the correct syntax.
Cause. A SWITCH SC command failed.
Effect. The switch card does not switch to the CROSSED position. SWCI waits for the
next command.
Recovery. Retry the command. If the command fails again, change the key switch on
the SCC to the LOCAL position and toggle the switch on the switch card to the crossed
position manually.
Cause. A SWITCH SC command failed.
Effect. The switch card does not switch to the STRAIGHT position. SWCI waits for the
next command.
Recovery. Retry the command. If the command fails again, change the key switch on
the SCC to the LOCAL position and toggle the switch on the switch card to the straight
position manually.
***ERROR*** Obey file file-name is not an edit file.
***ERROR*** Obey file file-name was not opened successfully.
***ERROR*** SC slot-number did not switch to the CROSSED
position.
***ERROR*** SC slot-number did not switch to the STRAIGHT
position.