Troubleshooting 76
For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers
Troubleshooting Guide located on the Documentation CD or on the HP website
(
http://www.hp.com/support).
WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary
information in the server documentation before removing, replacing, reseating, or modifying
system components.
Processor X Unsupported Wattage.
Audible beeps: 1 long, 1 short
Possible cause: Processor not supported by current server blade.
Action: Refer to the server blade documentation for supported processors. If the processor is supported,
remove the processor, update the system to latest ROM, and then reinstall the processor.