Operations 18
2.
Close the access panel latch. The access panel slides to a closed position.
3. Use a T-15 Torx screwdriver to tighten the access panel latch screw.
Remove the air baffle
CAUTION: For proper cooling, do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
1. Power down the server (on page 14).
2. Remove the power from the server:
a. Disconnect the power cord from the power source.
b. Disconnect the power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 14).
o Remove the server from the rack (on page 16).
4. Remove the access panel (on page 17).
5. Remove the air baffle.