Installing Hardware Options, Hot-Pluggable
2. Be sure that the cartridge power LED is off (2).
CAUTION: Do not remove a memory cartridge if the cartridge power LED is blinking
or is solid green. The system will halt.
3. Push the lever latch upward (3) to release the memory cartridge lever.
4. Pull the memory cartridge lever down (4).
5. Slide the cartridge out of the processor and memory module (5).
Figure 5-4: Removing the memory cartridge
WARNING: To reduce the risk of personal injury from hot surfaces, allow the
internal system components to cool before touching them.
HP ProLiant DL760 Generation 2 Server User Guide 5-9
HP CONFIDENTIAL
Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc
Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM