Hp ProLiant DL760 G2 Server Manuel d'utilisateur Page 171

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 299
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 170
Installing Hardware Options, Hot-Pluggable
4. Press the top (1) of the appropriate expansion slot release lever and open the
lever toward the rear (2) of the expansion slot.
5. Unseat the expansion board by pulling up on the plastic tab (3) and lift the board
out of the server (4).
Figure 5-27: Removing an I/O expansion board
6. If you are only removing the board, install an expansion slot cover. Close the slot
release lever. Ensure that the lever latches into the closed position.
7. If you are replacing the board, install the new I/O expansion board.
8. Close the slot release lever. Ensure that the lever latches into the closed position.
9. Reconnect any I/O cables to the new board.
10. Return power to the slot through the PCI Hot Plug button or software application.
The green LED will flash during the power-up transition and will turn on when
the power-up is complete. For more information about PCI Hot Plug LEDs, refer
to “PCI Hot Plug LED Indicators” earlier in this chapter.
11. Close the I/O lid.
5-56 HP ProLiant DL760 Generation 2 Server User Guide
HP CONFIDENTIAL
Writer: Bryce Miller File Name: f-ch5 Installing Options-Hot Pluggable.doc
Codename: Comet Part Number: 201264-001 Last Saved On: 6/17/03 9:47 AM