Dual domainalternative cabling
This example illustrates cabling for a dual-domain configuration in a pattern that offers a balance of
fault tolerance and performance. In this configuration, note the following:
A multi-port, dual-domain controller in the host and dual-port disk drives in the disk enclosure are
required for dual-domain deployments.
Cables from each I/O module in the disk enclosure to the server or controller enclosure and to
additional cascaded disk enclosures provide dual-domain connectivity.
The crossing of the cables between each disk enclosure offers both good fault tolerance and good
performance, but may be confusing to implement and maintain.
This example illustrates using a Small Form Factor disk enclosure with one additional cascaded
disk enclosure. When using Large Form Factor disk enclosures, more than one additional disk
enclosure can be cascaded. For more information, see the QuickSpecs for the Large Form Factor
disk enclosure.
IMPORTANT:
This cabling scheme is supported for use only when the disk enclosure is connected to a Smart Array
controller.
1. Host (server or controller
enclosure)
2. Primary disk enclosure
3. Cascaded disk enclosure
4. Primary path
5. Additional path