Configuration
Configuring the X.25 Link
Chapter 3 41
Step 3. Click on Modify Flow Control Settings to modify Switched and
Permanent VC flow control settings. The following dialog appears:
Figure 3-6
Step 4. Select either Modulo-8 or Modulo-128 to set level 3 Modulo parameters.
The default is Modulo-8.
The valid window-size values for Modulo-8 range from 1 to 7. For
Modulo-128, the valid window-size values range from 1 to 127.
NOTE Flow Control Negotiation must be enabled on the “Verify Level 3 Values”
dialog to allow the use of the negotiated flow control fields. If you do not
enable Flow Control Negotiation, the Default Packet Size and Default
Window Size values will be used.