7.4 Console-Reported Failures
Table 7–6 Troubleshooting Console-Reported Failures
Symptom Action
Power-up tests do not
complete.
Use error beep codes or console serial terminal to
determine what error occurred.
Check the power-up screen for error messages.
Console program reports an
error.
Interpret the error beep codes at power-up and
check the power-up screen for a failure detected
during self-tests.
Examine the console event log (use the more el
command) to check for embedded error messages
recorded during power-up.
If the power-up screen or console event log
indicates problems with mass storage devices or
PCI devices, or if devices are missing from the
show config display, see Section 7.10.
Use the SRM test command to verify the
problem.
Troubleshooting 7-7