HP 5300 Informations techniques Page 201

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 442
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 200
5
6
7
8
1
2
3
4
Power Over Ethernet (PoE) Operation
Configuring PoE Operation
1. Use the walkmib pethPsePortType.< slot-# > command to determine the MIB-
based port number for the port to which you want to assign a Configured
Type identifier. On the 5300xl switches the slot numbering is as follows:
Slot Slot Number
Used in the MIB
A
B
C
D
E*
F*
G*
H*
*5308xl only.
Note that in the MIB, 26 port numbers are assigned to each slot designa-
tion. Thus, for example, with PoE modules in slots “A” and “B”, the actual,
corresponding port numbers will be 1-24 and 27-50, respectively. (The port
numbers “25, “26”, “51, and “52” are reserved.)
2. Use the setmib pethPsePortType.< slot-# >.< port-# > -D < identifier-string >
command to configure the identifier you want for a specific port.
For example, suppose that you have a PoE xl Module installed in slot B and
want to assign the identifier “Wireless-1” to port 1 in this slot. To do so, you
would use the following commands:
11-13
Vue de la page 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 441 442

Commentaires sur ces manuels

Pas de commentaire