Troubleshooting
Diagnostic Tools
[timeout < 1-120 >]
For the current instance of traceroute, changes the timeout period the switch waits
for each probe of a hop in the route. For any instance of traceroute, if you want a
timeout value other than the default, you must specify that value. (Default: 5
seconds)
[probes < 1-5 >
For the current instance of traceroute, changes the number of queries the switch
sends for each hop in the route. For any instance of traceroute, if you want a probes
value other than the default, you must specify that value. (Default: 3)
A Low Maxttl Causes Traceroute To Halt Before Reaching the
Destination Address. For example, executing traceroute with its default
values for a destination IP address that is four hops away produces a result
similar to this:
Intermediate router hops
with the time taken for the
switch to receive
acknowledgement of
each probe reaching each
router.
Destination IP Address
Figure C-21. Example of a Completed Traceroute Enquiry
Continuing from the previous example (figure C-21, above), executing
traceroute with an insufficient maxttl for the actual hop count produces an
output similar to this: