◦ Not Supported - This storage system does not support reporting fan status through this
storage system backplane. The fan status is reported through the first backplane on this
storage system.
◦ Unknown - The Storage Agent is unable to determine the fan status.
• Speed displays the speed of the storage system backplane. The following values are possible:
Ultra3 - The storage system is capable of Ultra3 speeds.◦
◦ Ultra320 - The storage system is capable of Ultra320 speeds.
◦ SATA - The storage system is capable of SATA speeds.
◦ Unknown - The Storage Agents are unable to determine the storage system backplane
speed. You may need to upgrade your software.
• Drive Bays displays the number of bays on this storage system backplane.
• Temperature Status displays the current temperature status of the storage system backplane.
The following values are possible:
◦ OK - The temperature is within the normal operating range.
◦ Degraded - The temperature is outside of the normal operating range.
◦ Failed - The temperature has exceeded the safe operating temperature and could
permanently damage the storage system.
◦ Not Monitored - This storage system does not support temperature monitoring.
◦ Not Supported - This storage system does not support reporting the temperature status
through this storage system backplane. The temperature status is reported through the
first backplane on this storage system.
◦ Unknown - The Storage Agent is unable to determine the temperature status.
• Placement indicates the location of the storage system backplane. The following values are
valid:
◦ Internal - The storage system backplane is located inside the external array storage system
chassis.
◦ External - The storage system backplane is located outside the external array storage
system chassis in an external storage system.
◦ Unknown - The Storage Agent could not determine the location of the storage system
backplane.
• Power Supply Status displays the current status of the storage system backplane fault tolerant
power supply. The following values are possible:
◦ OK - The fault tolerant power supply is operating normally.
◦ Degraded - One of the redundant power supplies has failed. Replace the failed power
supply.
◦ Failed - All of the power supplies have failed. Replace the failed power supplies.
◦ Not Redundant - This storage system does not have a redundant power supply.
◦ Not Redundant (Power Supply 1 Missing) - This storage system does not have a redundant
power supply. The power supply in bay 1 is missing.
Storage agent 71