CXO7959
A
Figure 41 Locatio n of LED s tatus d is plays—enclosure rear
Table 21 LED status displays
EMU LEDs and icons The enclosure power (both the +5 VDC and +12 VDC) is present
and correct. There are NO enclosure faults
I/O module A and I/O modu le B LEDsFor information about I/O M odule LED status displays, see I/O
Module Status Displays.
Power supply and blower LEDs Both the power supply and the blower are operational.
Status monitoring and display
The major status monitoring capabilities of these enclosures include:
Displaying the enclosure status on the enclosure icons
Displaying the blower, power supply, EMU, drive, and I/O module status on the element LEDs
Detecting the installation of blowers, power supplies, drives, or I/O modules
Detecting the removal of blowers, power supplies, drives, or I/O module
Sensing enclosure internal temperatures
Sensing power supply voltage, current, and total power
Sensing ambient temperature
NOTE:
The ambient temperature is the temperature at the enclosure air intake, or the room temperature.
Enclosure status icons
TheenclosurestatusLEDsarelocatedontheenclosurebackplane. These LEDs illuminate the status icons
(see Table 22) in the front, lower right corner of the enclosures (see Figure 40)