Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 107

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 206
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 106
Single-Ended I/O Module
UltraSCSI RAID Enclosure 5–5
Controlling the Fault Bus
The I/O module controls fault bus operation in the following manner:
Provides a fault bus driver for improved signal transmission
Distributes the FAULT_CLK and FAULT_DATA signals from the
master enclosure to the expansion enclosures
Distributes the SHELF_OK and SWAP_L signals from the
expansion enclosures to the master enclosure
Error Reporting
The EMU monitors the status of the I/O modules for the following
error conditions:
Installation of incompatible I/O modules
TERMPOWER problems
Incompatible I/O Modules
An I/O module error condition exists if any of the following
conditions exist:
One or more nonoperating I/O modules
Installation of fewer than six operational I/O modules
All I/O modules are not the same type
When the EMU detects an I/O module error condition, it
automatically reports the problem to the array controller. Any
operational controller will automatically turn O
FF without
implementing procedures to clear the cache module. The result is that
the controller will cease to operate and be in an error state, a state that
can adversely affect the integrity of the data.
Note
Existance of an I/O module error condition prevents the
subsystem from operating.
Vue de la page 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 205 206

Commentaires sur ces manuels

Pas de commentaire