Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 48

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 206
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 47
Operating the UltraSCSI Enclosure
2–12 UltraSCSI RAID Enclosure
Fault Detection
Fault detection involves identifying errors and providing an indication
to the user for analysis. The following sections address how faults are
identified, descriptions of status LED indications, and in some cases,
possible corrective actions.
Error Detection, Reporting, and Analysis
The EMU and PVA constantly monitor the operational status of the
enclosure and its components. In some instances, automatic
corrective action implementation occurs. Status changes are indicated
to the user through a combination of LEDs, an EMU audible alarm,
and an optional
maintenance terminal
connected to the array
controller. Table 2–6 lists the major enclosure components and the
status items monitored by each component.
Table 2–6 Enclosure Status Monitoring
Component Status Monitored
Enclosure Intake air temperature
Exhaust air temperature
AC input power
Number of operational 180 W power supplies
Enclosure SCSI bus address
Power Output of dc power supplies
DC bus voltages
Termination I/O module dc voltage
Storage devices
(disk drive
SBBs)
Control signal response
Controller-detected fault condition
Removal
Installation
EMU Installation
PVA Installation
Vue de la page 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 205 206

Commentaires sur ces manuels

Pas de commentaire