Hp Array Controller HSG V8.7 Software Manuel d'utilisateur Page 160

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 206
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 159
Storage Devices
7–14 UltraSCSI RAID Enclosure
11. Starting at the left end, install all the disk drive SBB devices in
shelf 4 (devices 19 through 24).
12. If performing a cold swap, determine if there are expansion
enclosures. If there are no expansion enclosures, go to step 13.
If there are expansion
enclosures, turn O
N
all the ac
input boxes for each
expansion enclosure by
pressing
I
on each ac power
switch (C
ALLOUT
1).
13. On the master enclosure,
turn O
N
all the ac input
boxes by pressing
I
on each
ac power switch
(C
ALLOUT
1).
14. Verify that the amber device fault LED is O
FF
.
Note
When the SCSI bus is active and the disk drive SBB has power,
the green device activity LED is either O
N
, F
LASHING
, or O
FF
.
The amber device fault LED is O
FF
.
Table 7–4 Installing a Disk Drive SBB (Continued)