To install only the DSM component (when the Microsoft MPIO Framework already exists on
your system), edit the renamed default setup.iss le, as follows:
a. In line 34, replace Component-count=2 with Component-count=1.
b. Remove line 35.
c. In line 36, replace Component-1=DSM with Component-0=DSM.
4. If you want to install in a directory other than the default directory, replace szDir =
<Default_Target_Dir> with szDir = <User_Target_Dir>, in lines 27 and 32 of the setup.iss le.
5. If you want to disable the automatic reboot feature, edit the setup.iss, le as follows:
a. In line 50, replace Result=6 with Result=1.
b. In line 51, replace BootOption=3 with BootOption=0.
Uninstalling Smart Array Multipath software
To perform silent un-installation, complete the following steps:
1. Create a copy of the uninstall.iss le in the installation kit.
2. Rename this copy of the le as setup.iss.
3. If you want
to avoid the automatic reboot feature, edit the renamed setup.iss le, as follows:
a. In line 28, replace Result=6 with Result=1.
b. In line 29, replace BootOption=3 with BootOption=0.
NOTE:
On systems
congured either for Boot From SAN, or systems with page, hibernate, or dump les on the
disk array, uninstalling the last DSM may not remove all the related components. To work around this
issue, ensure that the MPIO framework is installed along with the DSM during the subsequent installation
of any supported HP MPIO DSM. Failure to do so can result in an unsuccessful system boot.
Static LUN balancing
The Smart Array Multipath software and Microsoft operating system support static LUN balancing. The
drives can be moved to specic paths locally using a Device Manager Extension (DME).
To balance LUNs with the DME, complete the following paths:
1. From the desktop, right-click My Computer.
2. Click Manage. The Device Manager window opens.
3. Click SCSI and RAID Controllers.
4. Right-click one of the array controller icons, and click Properties.
5. When the Properties window opens, click the Redundancy Conguration tab.
From the Redundancy Conguration tab, the administrator can view the following controller
information:
•Name
•Slotnumber
•Status
Slot number of redundant controller
Controller tree
6. In the controller tree, right-click one of the logical volumes, and then click Switch Path.The
system moves the logical volume to the other path.