pairsyncwait
Synchronization waiting command
Description The pairsyncwait command is used to confirm that a mandatory write (and
all writes before it) has been stored in the DFW (write) cache area of the
RCU.
The command gets the latest P-VOL async-CA sequence # of the main
control unit (MCU) side file and the sequence # of the most recently
received write at the RCU DFW (with the correct CTGID,
group or
raw_device) and compares them at regular intervals.
If the RCU sequence # exceeds the value of the designated MCU sequence
# within the time specified, this command reports a
0 return code (meaning
P-VOL/S-VOL synchronization to the desired point is achieved).
The –nowait option shows the latest sequence # (Q-marker) of the
designated MCU P-VOL and CTGID. The Q-marker is displayed in 10
hexadecimal characters.
Syntax pairsyncwait { -h | -q | -z | –g group | –d pair_vol | –d[g] raw_device
[ MU# ] | –d[g] seq# LDEV# [ MU# ] | –m marker | –t timeout | –nowait |
–nomsg | -fq }
Arguments –h Displays Help/Usage, and version information.
–q Terminates interactive mode and exits this command.
–z Makes this command enter interactive mode.
–zx (Not for use with MPE/iX and OpenVMS) Prevents you
from using RM in interactive mode. This option
terminates interactive mode upon RM shutdown.
–g group Used to specify a group name that is defined in the
configuration definition file.