This example disables all writing to volumes for the oralog group:
raidvchkset –g oralog –vg wtd
This example disables all writing and retention time for the oralog group:
raidvchkset –g oralog –vg wtd 365
This example disables guarding for the oralog group:
raidvchkset –g oralog –vg
This example disables writing for the oralog group.
raidvchkset -g oralog -vg wtd
This example disables writing and sets as retention time of 365 days.
raidvchkset -g oralog -vg wtd 365
This example releases all guarding for the oralog group.
raidvchkset -g oralog -vg
Error codes This command is rejected with EX_ERPERM by connectivity checking
between RAID Manager and the disk array.
The raidvchkset -vg option returns the following error code as well as
generic errors:
This means that the target volume mode cannot be changed, because
retention time prevents it. Confirm the retention time for the target volume
by using
raidvchkscan -v gflag.
Category Error Code Error Message Value
Volume Status
Unrecoverable
EX_EPRORT Mode changes denied
due to retention time
208