Hp 6633B Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Hp 6633B. HP 6633B User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 75
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
USERS GUIDE
Dynamic Measurement DC Source
HP Model 66332A
System DC Power Supply
HP Model 6631B, 6632B, 6633B, 6634B
For instruments with Serial Numbers:
HP 66332A: US36320401 and up
HP 6631B: US37470101 and up
HP 6632B: US36350826 and up
HP 6633B: US36390236 and up
HP 6634B: US36380206 and up
HP Part No. 5962-8196
Microfiche Part No. 5962-8197
Printed in USA: July 1999
Vue de la page 0
1 2 3 4 5 6 ... 74 75

Résumé du contenu

Page 1 - System DC Power Supply

USER’S GUIDEDynamic Measurement DC SourceHP Model 66332ASystem DC Power SupplyHP Model 6631B, 6632B, 6633B, 6634BFor instruments with Serial Numbers:H

Page 2 - Warranty Information

1 – Quick Reference10The Front Panel - At a Glancej14-characterdisplay shows outputmeasurements andprogrammed values.kAnnunciatorsindicate operatingmo

Page 3 - Safety Summary

1 – Quick Reference11Front Panel Number EntryEnter numbers from the front panel using one of the following methods:Use the arrow keys and knob to chan

Page 4

1 – Quick Reference12Front Panel AnnunciatorsCVThe output is operating in constant voltage mode.CCThe output is operating in constant current mode.Unr

Page 5 - Declaration Page

1 – Quick Reference13Front Panel Menus - At a GlanceADDRESS 7 Sets the HP-IB AddressINTF HPIB Selects an interface (HPIB or RS232)BAUDRATE 300 Selects

Page 6 - Printing History

1 – Quick Reference14SCPI Programming Commands - At a GlanceNOTE Most [optional] commands have been omitted for clarity. Refer to theProgramming Guide

Page 7 - Table of Contents

1 – Quick Reference15The Rear Panel - At a GlancejHP-IB (IEEE-488)interface connectorkRS-232 interfaceconnectorlINH/FLT (remoteINHibit / internalFauLT

Page 9 - Quick Reference

172General InformationDocument OrientationThis manual describes the operation of the HP Model 66332A Dynamic Measurement DC Sourceand the HP Model 663

Page 10 - The Front Panel - At a Glance

2 – General Information18Safety ConsiderationsThis dc source is a Safety Class 1 instrument, which means it has a protective earth terminal. Thattermi

Page 11 - Front Panel Number Entry

2 – General Information19DescriptionBoth the HP 66332A Dynamic Measurement DC Source and the HP 6631B/6632B/6633B/6634BSystem DC Power Supply combine

Page 12 - Immediate Action Keys

2Warranty InformationCERTIFICATIONHewlett-Packard Company certifies that this product met its published specifications at time of shipmentfrom the fac

Page 13 - 1 – Quick Reference

2 – General Information20the HP 6632A, 6633A, and 6634A Series dc power supplies (refer to appendix D in the theProgramming Guide). Dc source status r

Page 14

213InstallationInspectionDamageWhen you receive your dc source, inspect it for any obvious damage that may have occurredduring shipment. If there is d

Page 15 - The Rear Panel - At a Glance

3 - Installation22LocationThe outline diagram in figure 3-1 gives the dimensions of your dc source. The dc source must beinstalled in a location that

Page 16

Installation - 323Input ConnectionsConnect the Power Cord1. Unscrew the line fuse cap from the rear panel and verify that the fuse rating matches w

Page 17 - General Information

3 - Installation24Voltage DropsThe load wires must also be large enough to avoid excessive voltage drops due to the impedance ofthe wires. In general,

Page 18 - Options and Accessories

Installation - 325Under normal operation, the dc source senses the output voltage at the output terminals on the backof the unit. External sense ter

Page 19 - Description

3 - Installation26at the load. When using remote sensing, you must program the OVP trip voltage high enough tocompensate for the voltage drop between

Page 20 - Output Characteristic

Installation - 327Fast/Normal OperationA switch on the rear of the unit lets you switch between operating in either Fast mode or Normalmode. When se

Page 21 - Installation

3 - Installation28This rear panel connector, has a fault output port and an inhibit input port. The fault (FLT) output,also referred to as the DFI (di

Page 22 - Location

Installation - 329FLT OutputINH InputB) FLT Example with Multiple UnitsFLT OutputINH InputSwitch(NormallyOpen)INH CommonINH InputA) INH Example with

Page 23 - Output Connections

3Safety SummaryThe following general safety precautions must be observed during all phases of operation of this instrument.Failure to comply with thes

Page 24 - Remote Sense Connections

3 - Installation30Controller ConnectionsThe dc source connects to a controller either through an HP-IB or an RS-232 connector.HP-IB InterfaceEach dc s

Page 25 - Sense Leads

314Turn-On CheckoutIntroductionSuccessful tests in this chapter provide a high degree of confidence that the dc source is operatingproperly. For verif

Page 26 - OVP Considerations

4 - Turn-On Checkout32Checkout ProcedureThe test in this section checks for output voltage and current on the dc source.NOTE: To perform the checkout

Page 27 - INH/FLT Connections

Turn-On Checkout - 433Procedure Display Explanation6. Press 5, Enter VOLT:PROT 50.449V 0.145APrograms the OVP to 5 volts, which is less thanth

Page 28 - Digital I/O Connections

4 - Turn-On Checkout34In Case of TroubleError MessagesDc source failure may occur during power-on selftest or during operation. In either case, thedis

Page 29 - Figure 3-4. FLT/INH Examples

355Front panel OperationIntroductionHere is what you will find in this chapter:♦ a complete description of the front panel controls♦ front panel progr

Page 30 - Controller Connections

5 - Front Panel Operation36j Display14-character vacuum fluorescent display for showing output measurementsand programmed values.k AnnunciatorsAnnunci

Page 31 - Turn-On Checkout

Front Panel Operation - 537System KeysRefer to the examples later in this chapter for more details on the use of these keys.SYSTEMLocalErrorAddressSav

Page 32 - Checkout Procedure

5 - Front Panel Operation38Function KeysRefer to the examples later in this chapter for more details on the use of these keys.FUNCTIONInputMeterOVVolt

Page 33 - Turn-On Checkout - 4

Front Panel Operation - 539Metering KeysMetering keys control the metering functions of the dc source. When the unit is operating in frontpanel meter

Page 34 - In Case of Trouble

4SAFETY SYMBOLSDirect currentAlternating currentBoth direct and alternating currentThree-phase alternating currentEarth (ground) terminalProtective ea

Page 35 - Front panel Operation

5 - Front Panel Operation40Output Control KeysOutput control keys control the output functions of the dc source.Press this key to access the voltage m

Page 36

Front Panel Operation - 541Entry KeysRefer to the examples later in this chapter for more details on the use of these keys.ENTRY7410852.963-ClearEntry

Page 37 - System Keys

5 - Front Panel Operation42Examples of Front Panel ProgrammingYou will find these examples on the following pages:1 Setting the output voltage and cur

Page 38 - Function Keys

Front Panel Operation - 5432 - Querying and Clearing Output ProtectionThe dc source will disable its output if it detects an overvoltage or overcurren

Page 39 - Metering Keys

5 - Front Panel Operation44As previously mentioned, the HP 66332A dc source has the capability of measuring outputwaveform parameters such as peak, mi

Page 40 - Output Control Keys

Front Panel Operation - 5454 - Programming the Digital Output PortYour dc source is shipped with the output port function set to RIDFI mode. In this m

Page 41 - Entry Keys

5 - Front Panel Operation465 - Programming the Output Relay (option 760 only)Units with option 760 have isolation and polarity reversal relays connect

Page 42

Front Panel Operation - 5477 - Saving and Recalling Operating StatesNOTE: This capability is only available when the unit is set to the SCPI programmi

Page 44 - CURR:DET ACDC

ASpecificationsSpecificationsTable A-1 lists the specifications of the dc source. Specifications are warranted over the ambienttemperature range of 0

Page 45

5Declaration PageDECLARATION OF CONFORMITYaccording to ISO/IEC Guide 22 and EN 45014Manufacturer's Name: Hewlett-Packard CompanyManufacturer&apos

Page 46

A - Specifications50Supplemental CharacteristicsTable A-2 lists the supplemental characteristics, which are not warranted but are descriptions oftypic

Page 47

Specifications - A51Table A-2. Supplemental Characteristics (continued)Parameter HP 66332A HP6631B/6632B/6633B/6634BDynamic MeasurementAccuracyInstant

Page 48

A - Specifications52Table A-2. Supplemental Characteristics (continued)Parameter HP 66332A HP6631B/6632B/6633B/6634BDigital I/O CharacteristicsMaximum

Page 49 - Specifications

53BVerification and CalibrationIntroductionThis appendix includes verification and calibration procedures for the HP 66332A and HP6631B/6632B/6633B/66

Page 50 - Supplemental Characteristics

B - Verification and Calibration54DCCurrentmonitorVoltmeterLoadresistorDCAmpmeter-+LoadresistorDCAmpmeter-++-ExternalDC supplyA.B.C.+S +--S+ 240 VDC M

Page 51 - Specifications - A

Verification and Calibration - B55Table B-2. Verification Programming ValuesFull scale Voltage Full Scale Current Imax Isink6631B 8 10 10.238 - 10 A66

Page 52 - A - Specifications

B - Verification and Calibration565. Set the output current to its full scale value (see Table B-2).6. Divide the voltage drop across the current moni

Page 53 - Verification and Calibration

Verification and Calibration - B57Table B- 3. Verification Test Record for HP 6631BModel HP 6631B Report No._

Page 54

B - Verification and Calibration58Table B- 5. Verification Test Record for HP 6633BModel HP 6633B Report No.

Page 55

Verification and Calibration - B59Performing the Calibration ProcedureNOTE: The calibration procedure can only be performed using the SCPI languagecom

Page 56 - Current Sink Measurement

6Acoustic Noise InformationHerstellerbescheinigungDiese Information steht im Zusammenhang mit den Anforderungen derMaschinenläminformationsverordnung

Page 57

B - Verification and Calibration60Front Panel CalibrationThese procedures assume you understand how to operate front panel keys (see chapter 5).Enable

Page 58

Verification and Calibration - B61Current Programming and High-Range Measurement CalibrationAction Display13. Connect the appropriate current monitor

Page 59 - Front Panel Calibration Menu

B - Verification and Calibration62AC Current Measurement Calibration (HP 66332A only)Action Display26. Disconnect all loads from the dc source. Make s

Page 60 - Front Panel Calibration

Verification and Calibration - B63Changing the Calibration PasswordThe factory default password is 0. You can change the password when the dc source i

Page 62 - Calibration Error Messages

65CError MessagesError Number ListThis appendix gives the error numbers and descriptions that are returned by the dc source. Errornumbers are returne

Page 63 - Calibration Over the HP-IB

C - Error Messages66–131 Invalid suffix [unrecognized units, or units not appropriate]–138 Suffix not allowed –141 Invalid character data [bad charact

Page 64

Error Messages - C67Selftest Errors 0 through 99 (sets Standard Event Status Register bit #3)0 No error1 Non-volatile RAM RD0 section checksum failed2

Page 66 - C - Error Messages

69DLine Voltage ConversionWARNING: Shock Hazard Operating personnel must not remove instrument covers.Component replacement and internal adjustments

Page 67 - Error Messages - C

7Table of ContentsWarranty Information 2Safety Summary 3Acoustic Noise Information 6Printing History 6Table of Contents 7QUICK REFERENCE 9HP 66332A Dy

Page 68

D - Line Voltage Conversion70Install the Correct Line Fuse♦ Unscrew the line fuse cap from the rear panel and install the correct fuse.For 100/120 Vac

Page 69 - Line Voltage Conversion

71Index— —-- -- -- -- -- --, 43—+—+/- terminals, 23+S/-S terminals, 23—0—0 ... 9, 41—A—ac line conversion, 69accessories, 18ACDC current detector, 44a

Page 70 - Close the Unit

Index72OCP, 38Output, 40Output On/Off, 38OV, 40Prot Clear, 38Protect, 40Voltage, 40fuses, 23—G—ground, earth, 18guide, programming, 17guide, user’s, 1

Page 71

Index73saving operating states, 47selftest errors, 34sense connections, 25service guide, 18setting voltage/current, 42shift annun

Page 72

74HP Sales and Support OfficeFor more information, call your local HP sales office listed in your telephone directory or an HPregional office listed

Page 73 - Index

Manual UpdatesThe following updates have been made to this manual since the November 1997 printingindicated on the Printing History page.7/8/99Additio

Page 74 - HP Sales and Support Office

8TURN-ON CHECKOUT 31Introduction 31Using the Keypad 31Checkout Procedure 32In Case of Trouble 34Error Messages 34Line Fuse 34FRONT PANEL OPERATION 35I

Page 75 - Manual Updates

91Quick ReferenceHP 66332A Dynamic Measurement DC Source andHP 6631B/6632B/6633B/6634B System DC PowerSuppliesThe H

Modèles reliés 6632B | 6634B | 66332A |

Commentaires sur ces manuels

Pas de commentaire