show expander-status
Description This command is for use by or with direction from a service technician.
Shows diagnostic information relating to SAS Expander Controller physical channels, known as PHY
lanes. For each enclosure, this command shows status information for PHYs in I/O module A and
then I/O module B.
Syntax
show expander-status
Output Encl
Enclosure that contains the SAS expander.
Phy
Identifies a PHY's logical location within a group based on the PHY type. Logical IDs are 0–11 for
disk PHYs and 0–3 for inter-expander, egress, and ingress PHYs.
Type
DRIVE: Communicates between the expander and a disk.
EGRESS: Communicates between the expander and an expansion port or SAS Out port.
INGRESS: (Expansion module only) Communicates between the expander and an expansion
port.
INTER-EXP: (Controller module only) Communicates between the expander and the partner's
expander.
SC: (Controller module only) Communicates between the expander and the SC.
UNDEFINED: No status information is available.
UNUSED: Unused PHY.
Status
Disabled: The PHY has been disabled by a user or by the system.
Error: The PHY experienced an unrecoverable error condition or received an unsupported PHY
status value.
OK: The PHY is healthy.
Non-critical: Indicates that port is not connected, the port connector is defective, or the PHY
at the other end of the connection is disabled.
Not used: The module is not installed.
Unknown: The status is unknown.