HP Modular Smart Array 500 Starter Kit Guide de l'utilisateur Page 76

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 186
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 75
76
set advanced-settings
Description For API use, sets advanced system configuration options.
Syntax
set advanced-settings [auto-write-back enabled|disabled|on|off]
[background-scrub enabled|disabled|on|off]
[compact-flash-failure enabled|disabled|on|off]
[controller-failure enabled|disabled|on|off]
[dynamic-spares enabled|disabled|on|off] [emp-poll-rate rate]
[fan-failure enabled|disabled|on|off]
[host-cache-control enabled|disabled|on|off]
[missing-lun-response notready|illegal]
[partner-firmware-upgrade enabled|disabled|on|off]
[partner-notify enabled|disabled|on|off]
[power-supply-failure enabled|disabled|on|off] [smart enabled|disabled|on|off]
[super-cap-failure enabled|disabled|on|off] [sync-cache-mode immediate|flush]
[temperature-exceeded enabled|disabled|on|off]
[utility-priority low|medium|high]
Parameters auto-write-back enabled|disabled|on|off
Optional. Sets whether the cache mode automatically changes to write-back after the trigger
condition is cleared.
background-scrub enabled|disabled|on|off
Optional. Sets whether disks are automatically checked for disk defects to ensure system health.
compact-flash-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when CompactFlash
memory fails.
controller-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a controller
fails. The default is disabled.
dynamic-spares enabled|disabled|on|off
Optional. Sets whether the storage system will automatically designate a properly sized disk as a
spare.
emp-poll-rate rate
Optional. Sets the interval at which the storage system polls the EC (EMP) for status changes. The
default is 5 seconds.
fan-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a fan fails.
host-cache-control enabled|disabled|on|off
Optional. Sets whether the host can modify the cache setting. The default is disabled.
missing-lun-response notready|illegal
Optional. Sets the missing-LUN response which enables the host drivers to continue probing for LUNs
until they reach the LUN to which they have access.
notready: Sends a reply that there is a LUN where a gap has been created but that it's not
ready. Sense data returned is sensekey = 2, code = 4, qualifier = 3. This option is the default.
illegal: Sends a reply that there is a LUN but that the request is illegal. Sense data returned is
sensekey = 5, code = 25h, qualifier = 0.
partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
upgraded on the partner controller.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is disabled.
Vue de la page 75