HP Modular Smart Array 500 Starter Kit Guide de l'utilisateur Page 86

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 186
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 85
86
set disk-parameters
Description Selects a global disk Self-Monitoring Analysis and Reporting Technology (SMART) setting. Disks
equipped with this technology can alert the controller of impending disk failures. Changes to the
SMART setting take effect after a rescan or a controller reboot.
Syntax
set disk-parameters smart enabled|disabled|on|off|detect-only
Parameters smart enabled|disabled|on|off|detect-only
Enables or disables SMART monitoring for all disks in the storage system. Each disk added after
detect-only is set retains its SMART setting. Enabled by default.
Example Enable SMART:
# set disk-parameters smart on
Success: Command completed successfully
See also show disk-parameters